10
OVERALL DIMENSIONS
Width: 290 mm
Depth: 510 mm
CUT OUT DIMENSIONS
Width: 270 mm
Depth: 490 mm
SUPPLY CONNECTIONS
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Rapid Burner
Heat Input 3.0 kW (10236 BTU/HR)
Auxiliary Burner
Heat Input 1.0 kW (3413 BTU/HR)
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Rapid 42
Aeration adjustment none
Instructions for the Installer
Engineers technical data
APPLIANCE CLASS : 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
BURNER RAPID AUXILIARY
(large) (small)
POSITION MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.286 0.062 0.095 0.031
NOZZLE REFERENCE 119 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.65 1.0 0.33
NOMINAL FLOW
RATE g/h 202 47 72 24
NOZZLE REFERENCE 86 40 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Comentarios a estos manuales