• There is a risk of fire when the appliance is in
connection with an extension cable, an
adapter or a multiple connection. Make sure
that the ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
To prevent contact between the cable and the
appliance below the hob use the clamps which
are on the side of the cabinet.
A) Rigid copper pipe or flexible pipe of
stainless steel
Connection cable
To replace the connection cable use only the
special cable or its equivalent. The cable type
is: H05V2V2-F T90.
Make sure that the cable section is applicable
to the voltage and the working temperature. The
yellow / green earth wire must be approximately
2 cm longer than the brown (or black) phase
wire.
Building In
min. 55 mm
min. 650 mm
830 mm
min. 150 mm
30 mm
480 mm
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
Installing hob under the hood
If you install the hob under a hood,
please see the installation
instructions of the hood for the
minimum distance between the
appliances.
Possibilities for insertion
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections