Vista de pagina 4
5
SOLUTION
u Check that the unit is plugged in and the electrical
supply is switched on.
u Check the mains fuse has not blown.
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
u Check the main jet is not blocked and the burner
crown is clear of food particles.
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local Service
Centre.
SYMPTOM
n There is no spark when lighting the gas
n The gas ring burns unevenly
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.
Overall dimensions
Width: 580 mm.
Depth: 500 mm.
Height: 84 mm.
Cut out dimensions
Width: 550 mm.
Depth: 470 mm.
Instructions for the Installer
Engineer technical data
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50Hz supply, 3 core flexible cable with non
rewireable plug.
Appliance Gas supply: LPG 30 mbar
Appliance Class: 3
Appliance category: I 3
Burner Nominal Power LPG (Butane "A") Diameter Feeding
Tap. By-Pass Pressure
kW kCal/h Nozzle g/h mbar (*)
Auxiliary (dia. 42 mm.) 0,95 792 50 75 28
Semi-rapid (dia. 57 mm.) 1,60 1329 65 126 35 30
Powered Rapid (dia. 90 mm.) 2,9 2406 85 228 45
(*) 1 mbar = 10 mm. water coloumn.