Electrical connections
Prior to making the electric al connection, make
sure that:
- The protection fuse and the domestic wire
system are suitable to carry the total electric load
of the oven (see rating plate).
- Your domestic wiring system has an efficient
earth connection in compliance with the rules
and laws in force.
- The wall socket or the omnipole switch used for
the electrical connection can easily be reached
after the oven is built in.
The appliance is delivered without an electric
supply cable, therefore, you will have to fit to it a
supply cable with standard plug, suitable for the total
electric load shown on the rating plate.
The plug is to be inserted into a suitable wall
socket.
If you require a direct connection to the electric
network (mains), it will be necessary to fit between
the appliance and the mains an omnipole switch, aith
a minimum gap between contacts of 3 mm. suitable
for the required load and in compliance with rules in
force. The green 1 yellow ground wire must not be
interrupted by the switch.
The supply cable must in all cases be laid out in
such a way as to ensure that it does not reach at any
given point a temperature 50°C higher than the
ambient temperature.
The manufacturer disclaims any liability in
case these accident-preventing rules are not
observed.
Suitable power supply cables are the following
types, considering the respective necessary section
of cable.
• H07 RN-F
• H05 RN-F
• H05 RR-F
• H05 VV-F
• H05 V2V2-F (T90)
Connecting the terminal board
The appliance incorporates an easily accessible
6-pole terminal board whose jumpers (bridges) are
already pre-set for operation on 400 V three-phase
with neutral wire. In case where different mains
voltage is present, the jumpers on the terminal board
must be arranged as shown in the diagram.
The ground cable must be connected to terminal
.
After connecting the supply cable to the terminal
board, secure it with a junction clamp.
230V 3~
1 2 3 4 5
L1 L2 L3 PE
230V 1~
1 2 3 4 5
L1 N PE
400V 2N~
1 2 3 4 5
L1 L2 N PE
400V 3N~
1 2 3 4 5
L1 L2 L3 N PE
Section
of cable
(min.)
4 x 1.5 mm
2
Section
of cable
(min.)
3 x 2.5 mm
2
Section
of cable
(min.)
4 x 2.5 mm
2
Section
of cable
(min.)
5 x 1.5 mm
2