INSTALLATION
Positioning
Remove all the packaging and install the cooker
in a dry, ventilated room not near curtains, paper,
alcohol, petrol etc.
The appliance must be set on a heatproof, level
floor.
This appliance is approved to class “Y” (EN60335-
2-6 plus subsequent amendments). This means
that the appliance can be installed up against a
wall with a distance of not less than 20mm (fig 2)
or inserted between 2 walls (fig 1). Only one side
wall can exceed the height of the work surface
and it must have a distance of 70mm from the
edge of the cooker.
Any walls of the adjacent kitchen furniture and the
wall behind the cooker must be made with heat
resistant material that can withstand a minimum
overtemperature of 65K.
Any overhanging cabinetry installed above the
work surface must be located at a distance of no
less than 700mm.
The cooking appliance must be fitted
with a stability chain firmly secured to the
wall
Ventilation
The room containing the cooker should have an
air supply in accordance with B.S. 5440: Part 2:
Current Editions.