OVERALL DIMENSIONS
Width: 680 mm
Depth: 510 mm
Height: 85 mm
CUT OUT DIMENSIONS
Width: 560 mm
Depth: 480 mm
Thickness: 30 mm
Instructions for the Installer
Engineers technical data Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand
corner
Electric:
230-V 50 Hz supply, 3 core flexible cable with
non rewireable plug.
Appliance Gas supply: LPG 30 mbar
Appliance Class: 3
Appliance category: I 3
Burner Nominal Power
LPG (Butane "A")
Diameter Feeding
Tap. By-Pass Pressure
kW kCal/h Nozzle g/h mbar (*)
Auxiliary 0,95 814 50 75 28
Semi-rapid 1,60 1368 65 126 35 30
Rapid 2,45 2095 80 193 45
Triple crown 3,60 3080 98 284 56
(*) 1 mbar = 10 mm. water coloumn
Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local
Service Centre.
SYMPTOM
There is no spark when lighting the gas
The gas ring burns unevenly
SOLUTION
Check that the unit is plugged in and the
electrical supply is switched on
Check the mains fuse has not blown
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Check the main jet is not blocked and the
burner crown is clear of food particles.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.