Zanussi ZGG96624XA Manual de usuario Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.
Technical data
Hob dimensions
Width 894 mm
Depth 510 mm
Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Rapid 42
Semi-rapid 32
Auxiliary 28
Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 13 kW
Gas replacement: G30 (3+) 28-30 mbar = 931 g/h
G31 (3+) 37 mbar = 914 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2H3+
Gas connection: G 1/2"
Appliance class: 3
Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4,0 1,4 146
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
14 www.zanussi.com