Depth 510 mm
OTHER TECHNICAL DATA
TOTAL POWER:
Gas original:
G20/G25 (2E+) 20/25 mbar (BE) = 10,5 kW
G20 (2E) 20 mbar (LU) = 10,5 kW
Gas replacement: G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2E+3+ (BE)
I2E (LU)
Gas connection: R 1/2"
Appliance class: 3
BYPASS DIAMETERS
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Semi-rapid 32
Auxiliary 28
GAS BURNERS FOR NATURAL GAS G20/G25 20/25 MBAR (BE) - G20 20 MBAR (LU)
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Triple Crown 3,8 1,4 146
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
GAS BURNERS FOR LPG G30/G31 28-30/37 MBAR
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar G31 37 mbar
Triple
Crown
3,8 1,4 98 276 271
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71