Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
1/100 mm
Rapid 2,9 0,75
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71
ENVIRONMENTAL CONCERNS
Recycle the materials with the symbol . Put
the packaging in applicable containers to
recycle it. Help protect the environment and
human health and to recycle waste of electrical
and electronic appliances. Do not dispose
appliances marked with the symbol with the
household waste. Return the product to your
local recycling facility or contact your municipal
office.
www.zanussi.com 15
*