z Risk of injury from electrical current.
Loose and inappropriate plug and socket connections can make the ter-
minal overheat.
Have the clamping connections correctly installed by a qualified electri-
cian.
Use strain relief clamp on cable.
In the event of single-phase or two-phase connection, the appropriate
mains cable of type H05BB-F Tmax 90°C(or higher) must be used.
If this appliance’s mains cable is damaged, it must be replaced by a spe-
cial cable (type H05BB-F Tmax 90°C; or higher). The latter is available
from the Customer Care Department.
A device must be provided in the electrical installation which allows the ap-
pliance to be disconnected from the mains at all poles with a contact open-
ing width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw type
fuses are to be removed from the holder), earth leakage trips and contac-
tors.