Zanussi ZOU10301XK Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
Building In
589
598
594
114
19
21540
570
558
min. 550
20
600
min. 560
3
9
Securing the appliance to the cabinet
A
B
Electrical installation
The manufacturer is not responsible
if you do not follow the safety
precautions from the Safety
chapters.
This appliance is supplied without a main plug
and a main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal board.
The jumpers (bridges) are set for operation on a
400 V three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1 2 3 4 5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the
ground cable to the terminal. After you connect
the supply cable to the terminal board, attach it
with a junction clamp.
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1 N
L2
L1 N
N
L2
L3
L1 L2 L3
PE
PE
PE
PE
www.zanussi.com 29
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 47 48

Comentarios a estos manuales

Sin comentarios