INSTALLATION
WARNING! Refer to Safety chapters.
BUILDING UNDER
CAUTION! Only a qualified and
competent person must do the
installation of the appliance. If you do
not contact a qualified or competent
person, the guarantee becomes invalid
if there is damage.
Before you install the appliance, fit it with the
applicable hob from the table.
Type Maximum power
ZES 6040 5800 W
ELECTRICAL CONNECTION WITH THE HOB
The hob connection socket is at the top of the oven
cabinet. The hob has connection leads for the
cooking zones and the ground cable. The leads
have plug-in connectors. To connect the hob to the
oven, plug the connectors into the correct oven
sockets. The design of the plugs and sockets
prevents incorrect connections.
BUILDING IN
589
598
594
114
19
21540
570
558
min. 550
20
600
min. 560
3
9
SECURING THE APPLIANCE TO THE
CABINET
ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied without a main plug and
a main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate.
CONNECTING THE TERMINAL BOARD
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1 2 3 4 5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the ground
15