Dimension mm
B 150
Technical Data
Dimensions
Height 865 mm
Width 600 mm
Depth 600 mm
Total electricity power 3315,6 W
Voltage 230 V
Frequency 50 Hz
Gas Category II2E+3+
Gas Supply G20/G25 (2E+) 20/25
mbar
G30/G31 (3+)
28-30/37 mbar
By-pass diameters
Burner Ø By-pass in 1/100
mm.
Auxiliary 29
Semi-rapid 32
Rapid 42
Gas burners
Burner Normal
power
Reduced
power
Type of gas Pres-
sure
Inj. Diam-
eter
Cons.
kW kW mbar mm g/h
Auxiliary burn-
er
1,00 0,35 Natural Gas
G20
20 0,70 -
0,95 0,35 Natural Gas
G25
25 0,70 -
1,00 0,35 Butane G30 28–30 0,50 72,71
1,00 0,35 Propane G31 37 0,50 71,41
Semi-rapid
burner
2,00 0,43 Natural Gas
G20
20 0,96 -
1,85 0,43 Natural Gas
G25
25 0,96 -
2,00 0,43 Butane G30 28–30 0,71 145,43
2,00 0,43 Propane G31 37 0,71 142,83
Rapid burner 3,00 0,72 Natural Gas
G20
20 1,19 -
2,75 0,72 Natural Gas
G25
25 1,19 -
3,00 0,72 Butane G30 28–30 0,88 218,14
3,00 0,72 Propane G31 37 0,88 214,24
Gas Connection
Choose fixed connections or use a flexible pipe
in stainless steel in compliance with the regula-
tion in force. If you use flexible metallic pipes,
be careful they do not come in touch with mo-
bile parts or they are not squeezed.
Flexible nonmetal pipes connection
If it is possible to easily and fully control the gas
connection, you can use a flexible pipe. You
must tightly attach the flexible pipe by clamps.
To install, use a pipe holder. Make sure that you
tightly attach the pipe holder to the gasket, and
15