Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Triple Crown 67
Oven 50
Grill 59
Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.80 146
Semi-rapid 2.0 0.45 96
Auxiliary 1.0 0.35 70
Oven 2.5 1.0 104
Grill 2.4 1.5 104
Gas burners for LPG G30 28-30 mbar
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.80 101
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 2.5 1.0 75
Grill 2.4 1.5 75
Gas connection
The gas pipe in the appliance has two endings.
You can connect the gas supply to either one of
them. The pipe that is not used must be
clogged with the pipe closer, which added to
the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible metallic
pipes, make sure they do not come in touch
with mobile parts and they are not squeezed.