This cooker must be earthed.
The manufacturer declines any liability should
these safety measures not be observed.
This cooker is designed to be connected to a
230/400V, 50Hz AC electrical supply.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the rating
plate.
Note:
In case of a direct connection to the mains you have
to interpose an omnipolar switch with a minimum
opening between contacts of 3 mm must be done
under over voltage category III condition.
The switch should be sited within 2m of the hob and
be easily accessible upon completion of the
installation.
The yellow-green grounding cable has not to be
interrupted by the switch.
NOTE: The earth wire should be about 10-12 cm
longer than the live and neutral wires.
To use cable type H05 RR-F with the section
indicated in the table no.1.
Important
If the supply cord is damaged it must be
replaced by the manufacturer or its service
agent or a similarly qualified person in order
to avoid a hazard.
Ensure that the supply cord is not in contact with
any part of the hatched area shown in the
diagram.
BACK OF THE COOKER
Before connecting check that:
fuse and household electric installation can bear the
charge of the appliance (see rating plate);
The socket or the omnipolar switch used for
connection is easily reachable when the appliance
is installed.
How to proceed?
Unscrew and remove the protective cover at the
back of the appliance;
Connect the power cord to the terminal of the
cooker according to the table no.1;
Fix by means of cable clamp;
Make sure that the connection to the terminal is
matching the network power;
Remount and screw the protective cover at the back
of the appliance
Table no. 1
Nominal tension 230V ~/400V 3N/ 230V 3~/400V 2N~
Connection type Single phase Tri-phase
Tri-phase Y 3 ph.
+ neutral
Tri-phase Y 2 ph.
+ neutral
Cable connection to
the terminal plate
1 2 3 4 5
L1
N
L3
5
1 2
3 4
L1 L2
3
1
L3 L1
4 5
N
L2
2
4 5
N
2 3
L2 L1
1
Network voltage 230V ~ 230V 3~ 400V 3N 400V 2N~
Voltage of heating
elements
230V 230V 230V 230V
Fusible capacity 35 A 3x20 A 3 x 16 A 2x25 A
Cable section 3 x 6 mm
2
4 x 4 mm
2
5 x 2,5 mm
2
4 x 4 mm
2