13
This cooker must be earthed.
The manufacturer declines any liability should
these safety measures not be observed.
This cooker is designed to be connected to a
230/400V, 50Hz AC electrical supply.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the rating
plate.
Note:
In case of a direct connection to the mains you have
to interpose an omnipolar switch with a minimum
opening between contacts of 3 mm must be done
under over voltage category III condition.
The switch should be sited within 2m of the hob and
be easily accessible upon completion of the
installation.
The yellow-green grounding cable has not to be
interrupted by the switch.
NOTE: The earth wire should be about 10-12 cm
longer than the live and neutral wires.
To use cable type H05 RR-F with the section
indicated in the table no.1.
Important
If the supply cord is damaged it must be
replaced by the manufacturer or its service
agent or a similarly qualified person in order
to avoid a hazard.
Ensure that the supply cord is not in contact with
any part of the hatched area shown in the
diagram.
BACK OF THE COOKER
Before connecting check that:
• fuse and household electric installation can bear the
charge of the appliance (see rating plate);
• The socket or the omnipolar switch used for
connection is easily reachable when the appliance
is installed.
How to proceed?
• Unscrew and remove the protective cover at the
back of the appliance;
• Connect the power cord to the terminal of the
cooker according to the table no.1;
• Fix by means of cable clamp;
• Make sure that the connection to the terminal is
matching the network power;
Remount and screw the protective cover at the back
of the appliance
Table no. 1
Nominal tension 230V ~/400V 3N/ 230V 3~/400V 2N~
Connection type Single phase Tri-phase
Tri-phase Y 3 ph.
+ neutral
Tri-phase Y 2 ph.
+ neutral
Cable connection to
the terminal plate
1 2 3 4 5
L1
N
L3
5
1 2
3 4
L1 L2
3
1
L3 L1
4 5
N
L2
2
4 5
N
2 3
L2 L1
1
Network voltage 230V ~ 230V 3~ 400V 3N 400V 2N~
Voltage of heating
elements
230V 230V 230V 230V
Fusible capacity 35 A 3x20 A 3 x 16 A 2x25 A
Cable section 3 x 6 mm
2
4 x 4 mm
2
5 x 2,5 mm
2
4 x 4 mm
2