Zanussi ZKT630 D Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20
1 Safety Instructions for the Installer
A fixture must be provided in the electrical instal-
lation which allows the appliance to be discon-
nected from the mains at all poles with a contact
opening width of at least 3 millimetres.
Suitable isolation devices include, e.g. cut-outs,
fuses (screw type fuses are to be removed from
the holder), earth leakage trips and contactors.
In respect of fire protection, this appliance corre-
sponds to type Y (IEC 335-2-6). Only this type of
appliance may be installed with a high cupboard
or wall on one side.
It is not permitted to fit drawers underneath the
cooking surface.
Shock protection must be provided by the instal-
lation.
The kitchen unit in which the appliance is fitted
must satisfy the requirements of DIN 68930 in
respect of stability.
For protection against moisture, all cut surfaces
are to be sealed with a suitable sealant.
On tiled work surfaces, the joints in the area
where the hob sits must be completely filled with
grout.
On natural, artificial stone, or ceramic tops, the
snap action springs must be bonded in place
using sythetic resin or separate application adhe-
sive.
Ensure that the seal is correctly seated in the
frame and that it is seated against the work sur-
face without leaving any gaps. Additional silicon
sealant must not be applied, this will make remo-
val more difficult in the event of the need for ser-
vice.
To remove the hob, it must be pressed out from
below.
Electrical Connection
Only the supply lead fitted on the recess may be
used for connecting the unit. Replacement cables
can only be obtained from Zanussi customer service.
A fixture must be provided in the electrical installa-
tion which allows the appliance to be disconnected
from the mains at all poles with a contact opening
width of at least 3 millimetres. Suitable isolation
devices include, e.g. cut-outs, fuses (screw type
fuses are to be removed from the holder), earth lea-
kage trips and contactors.
1
Attention! Make the electrical connection in
accordance with the connection diagram.
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21

Comentarios a estos manuales