Gas replacement: G30/G31 (3B/P) 30/30 mbar
Bypass diameters
BURNER
Ø BYPASS
1)
1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Oven 44
1) Type of bypass depends on model.
Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 2.6
0.72 / 0.75
1)
113
Semi-rapid
2.0 / 1.9
1)
0.43 / 0.45
1)
96
Auxiliary 1.0 0.35 70
Oven 2.7 0.90 120
Grill 1.9 - 108
1) Type of bypass depends on model.
Gas burners for LPG G30 30 mbar
BURNER NORMAL
POWER kW
REDUCED POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 2.5 0.72 77 181.78
Semi-rapid 2.0 0.43 71 145.43
Auxiliary 1.0 0.35 50 72.71
Oven 2.7 0.90 80 196.33
Grill 1.9 - 71 138.16